Laser cutting machine cooling machine OPS

Laser cutting machine cooling machine failure cause failure point out
1. The inlet pipe is blocked and inhaled air
2. Import and export pipeline reverse connection
3. The pump motor reversal
4. The motor and pump axis wear
5. Use of the product does not conform to specifications
6. The oil tank liquid level below the lower limit
7. Oil and water filter group
8. Oil and water pressure floating ball fault detector switch 1. Inspection. Clean up the oil. Lock line
2. Check the direction connection of import and export right
3. The product of thermoelectric yi (51 p) below red. White line
4. Update the pump motor
5. Please form suitable for oily, instruction contained in
6. Regularly check oil tank liquid level
7. Replace or clean the filter
8. Replace the floating ball pressure detector switch
 